Abstract
Background Sepsis is an emergency state in response to an infectious process ultimately leadingto multiorgan dysfunction and death. There is an urgent need for sepsis detection methods, especially in emergency settings. To fill this gap, monocyte distribution width (MDW) was studied as an early indicator of sepsis. Aim To evaluateMDW as an early marker of sepsis. Material and methods This was a prospective observational study including critically ill adult patients who presented to the emergency department. MDW was measured using a DxH 900 Hematology Analyser (Beckman Coulter Inc., Miami, FL). Abnormal MDW (>20.0) was considered a predictor of sepsis. Results A total of 148 patients were included and categorizedaccording to the Sepsis-2 and Sepsis-3 criteria, as having sepsis (25.6%), sepsis with shock (21.6%), and non-sepsis (52.8%). In patients with sepsis with and without shock, MDW was 28.28 ± 9.20 and 28.02 ± 9.01, respectively, significantly higher than in patients without sepsis (p < 0.001). The diagnostic accuracy value of MDW testing for early sepsis detection was highly significant (0.74, p < 0.000). Conclusion MDW can be used as a marker for the early prediction of sepsis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.