Abstract

Inspections of Sweden’s longest suspension bridge, the approximately ten years old High Coast Suspension Bridge, have shown that the main bridge bearings have been seriously affected by wear. A monitoring program was therefore initiated in 2005 to measure actual vertical loads acting on the bearings as well as the tension in the first hangers of the bridge. This article describes the instrumentation and the calibration process. Interesting results from several months of monitoring are presented. Results show that the measured loads on the bearings due to permanent loads are in very good agreement with what was predicted during design. However, very large loads and large dynamic effects were registered from passing lorries.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.