Abstract

As part of a contract for air quality monitoring at an urban waste incinerator neighborhood, measurements of PM10 and PM2.5 are being routinely evaluated. Two samples are collected for 24h at the weekend and a working day, using a Gent collector, which separates the particulate in two fractions: PM2.5 and PM2.5–10. Filters are polycarbonate Nuclepore, sized 47mm, which, for analysis, are cut as: one half to be analyzed by instrumental neutron activation analysis (INAA) and one quarter for proton induced X-rays emission (PIXE). Both techniques are multielemental determining together around 25 chemical elements. Comparison of results is just possible for potassium, iron and zinc, which are compared in this work. A better agreement is obtained in PM2.5 suggesting a homogeneity trend. Fe and K compare quite well and Zn may show quite different results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.