Abstract

Temperature, forces and acoustic emission measurements are employed for research into the mechanics of grinding and for process monitoring. Temperature measurement in grinding presents a number of challenges especially in wet grinding. Fluid can affect the precision of the measurement when using infrared technique or make a short circuit when using grindable thermocouple. This paper highlights the previous temperature measurement methods and introduces a new one for measuring. Acoustic Emission technique has the capability to provide efficient real-time knowledge and monitoring of the grinding process. AERMS values were used to analyses the process characteristics. This paper explores the relations between temperature, force, acoustic emission and roughness.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.