Abstract
This investigation retrospectively assessed inexpensive non-invasive qualitative methods to monitor the ingestion of anti-tuberculosis drugs isoniazid, rifampicin and rifapentine. Results showed that commercial test strips detected the isoniazid metabolites isonicotinic acid and isonicotinylglycine as efficiently as the isonicotinic acid method in 150 urine samples. The presence of rifamycins in urine samples ( n = 1085) was detected by microbiological assay techniques and the sensitivity compared to the n-butanol extraction colour test in 91 of these specimens. The proportions detected by the two methods were significantly different and the sensitivity of the n-butanol procedure was only 63.8% (95% CL 51.2–76.4%) as compared to that of the superior microbiological method. Final validation ( n = 691) showed that qualitative assays measure isoniazid and rifamycin ingestion with an efficiency similar to high-performance liquid chromatography. The qualitative procedures may therefore be valuable in clinical trials and in tuberculosis clinics to confirm drug ingestion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.