SummaryUltrasonic velocity profiling with pressure difference (UVP‐PD) was demonstrated to be a successful, non‐invasive, in‐line measurement system for instantaneous velocity and rheological flow profiling of complex, opaque fat blends. Model systems of 25% Akomic, 75% rapeseed oil; and 25% Akomic, 74% rapeseed oil and 1% Grindsted® Crystalliser 110 were compared under real process conditions with UVP‐PD. Results indicated that the sample containing the crystalliser had twice the viscosity of the control. These in‐line results are in agreement with previous off‐line results, and offer the chance to probe the mechanics of fat blend physics under real, dynamic conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.