Abstract
In this study, a fast bioassay using the ECOTOX system to evaluate biological safety of waste water samples from different sources was performed. This biological system works full automatically to test water quality. The system uses the image analysis of movement behavior of the flagellate Euglena gracilis as a model organism. The measured parameters are cell motility, velocity, orientation (r-value, upward swimming and alignment) as well as cell form (compactness). In most tested waste samples, precision of orientation (r-value) is inhibited at concentrations which showed less effect on the other parameters. Motility and compactness were noticed to be the least inhibited parameters in response to waste water samples. The results of waste treatment plants revealed the efficiency of the used purification system. Movement as well as orientation parameters in E. gracilis showed high sensitivity toward chlorine. The order of sensitivity was motility > velocity > r-value > upward swimming with EC50 values of 0.69, 0.81, 0.85, and 1.78 mg L−1, respectively. ECOTOX with its test organism (E. gracilis) provides an automatic, fast and sensitive system to monitor water samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.