Abstract

Study objective: The arousal state changes during spinal anesthesia. It is not clear if BIS and others devices could monitor the induced neuroaxial blockade sedation. Our objective was evaluate BIS and entropy values when spinal anesthesia is done. Design: We developed a prospective study. Patients: 40 patients were included in this study, ASA I-III, over 60 years old, undergoing spinal anesthesia, without premedication scheduled for orthopedics procedures. Intervention: Spinal anesthesia was performed with the unseated volunteer in the lateral decubitus position with a 25-gauge Whitacre needle at L2-L3 space, andanesthesia was done with 12 mg of 0.5% hyperbaric bupivacaine. Patients were positioned supine for 5 min after spinal anesthesia. Measurements: Observer’s Assessment of Alertness/Sedation OAA/S, response (RE) and state entropy (SE) and BIS, and standard hemodynamic measures. Main results: Statistical analysis were performed by Wilcoxon test or ANOVA, p 0.05). Conclusions: The spinal anesthesia decreased the cortical activity and these were founded by OAA/S scale and depth anesthetics monitors. OAA/S was a more sensitive value of this induced sedation. BIS and RE showed a better correlation with OAA/S scale than SE.