Measurements of aerosol particles in the air of an urban area in the UK have been made. Ambient air was sampled and the particulates measured after passing through a size selective PM10 inlet. Particle mass was measured using a Tapered Element Oscillating Microbalance (TEOM). Particle number and size distributions were obtained using an Electrical Aerosol Analyser (EAA) and an Aerodynamic Particle Sizer (APS). Measurements were also made of local meteorological parameters. Fine particle number concentrations were found to show better temporal agreement, including diurnal variation, with particle mass concentrations than the coarser particle number concentrations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.