Abstract

We present in this paper the results of monitoring the construction process of a steel incrementally launched bridge located at the Kadagua Valley in Bilbao (Spain) with FBG sensors. The installation of FBG strain and temperature sensors was done in order to obtain deformation and temperature variations during the launching operation. The deflection recovery process was also monitored. The setup carried out in the sensors installation process consists of five optical channels (one for each cross section monitored) and a multiplexed structure of nine strain sensor in each optical channel. Temperature sensors were also installed in order to measure temperature variation of the steel structure but also for thermal compensation for the FBG strain sensors. The installation of the optical sensors is explained in detail including cleaning, bonding and connection of the almost fifty sensors installed in this structure. We also are going to explain the behaviour of the steel structure by presenting several figures showing the strain values for each sensor taken in real time during the launching of the bridge.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.