Abstract

Tissue oxygen measurement and positron emission tomography (PET) were evaluated as methods for predicting ischemia in microvascular free flaps of the head and neck. Ten patients with head and neck squamous cell cancer underwent resection of the tumour followed by microvascular reconstruction with a free flap. Tissue oxygenation of the flap (P(ti)O(2)) was continuously monitored for three postoperative (POP) days and the blood flow of the flap was assessed using oxygen-15 labelled water and PET. In three free flaps a perfusion problem was suspected due to a remarkable drop in P(ti)O(2)-values, due to two anastomosis problems and due to POP turgor. No flap losses occurred. During the blood flow measurements with PET [mean 8.5 mL 100 g(-1) min(-1 )(SD 2.5)], the mean P(ti)O(2) of the flaps [46.8 mmHg (SD 17.0)] appeared to correlate with each other in each patient (p<0.05, n=10). Tissue oxygenation measurement is a feasible monitoring system of free flaps. The perfusion-study with PET correlates with P(ti)O(2)-measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.