Abstract

By immobilizing glycopolymers onto the surface of the recently developed plasmonic field effect transistor (FET), the recognition between lectins and surface-immobilized glycopolymers can be detected over a wide dynamic range (10-10 to 10-4 M) in an environment that resembles the glycocalyx. The binding to the sensor surface by various lectins was tested, and the selectivities and relative binding affinity trends observed in solution were maintained on the sensor surface, and the significantly higher avidities are attributed to cluster-glycoside effects that occur on the surface. The combination of polymer surface chemistry and optoelectronic output in this device architecture produces amongst the highest reported detection sensitivity for ConA. This work demonstrates the benefits that arise from combining emerging device architectures and soft-matter systems to create cutting edge nanotechnologies that lend themselves to fundamental biological studies and integration into point-of-use diagnostics and sensors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.