Abstract

Mechanical ventilation (MV) is a lifesaving supportive intervention in the management of acute respiratory distress syndrome (ARDS), buying time while the primary precipitating cause is being corrected. However, MV can contribute to a worsening of the primary lung injury, known as ventilation-induced lung injury (VILI), which could have an important impact on outcome. The ARDS lung is characterized by diffuse and heterogeneous lung damage and is particularly prone to suffer the consequences of an excessive mechanical stress imposed by higher airway pressures and volumes during MV. Of major concern is cyclic overdistension, affecting those lung segments receiving a proportionally higher tidal volume in an overall reduced lung volume. Theoretically, healthier lung regions are submitted to a larger stress and cyclic deformation and thus at high risk for developing VILI. Clinicians have difficulties in detecting VILI, particularly cyclic overdistension at the bedside, since routine monitoring of gas exchange and lung mechanics are relatively insensitive to this mechanism of VILI. Expired CO2 kinetics integrates relevant pathophysiological information of high interest for monitoring. CO2 is produced by cell metabolism in large daily quantities. After diffusing to tissue capillaries, CO2 is transported first by the venous and then by pulmonary circulation to the lung. Thereafter diffusing from capillaries to lung alveoli, it is finally convectively transported by lung ventilation for its elimination to the atmosphere. Modern readily clinically available sensor technology integrates information related to pulmonary ventilation, perfusion, and gas exchange from the single analysis of expired CO2 kinetics measured at the airway opening. Current volumetric capnography (VCap), the representation of the volume of expired CO2 in one single breath, informs about pulmonary perfusion, end-expiratory lung volume, dead space, and pulmonary ventilation inhomogeneities, all intimately related to cyclic overdistension during MV. Additionally, the recently described capnodynamic method provides the possibility to continuously measure the end-expiratory lung volume and effective pulmonary blood flow. All this information is accessed non-invasively and breath-by-breath helping clinicians to personalize ventilatory settings at the bedside and minimize overdistension and cyclic deformation of lung tissue.

Highlights

  • Respiratory Distress SyndromeReviewed by: Penny Andrews, Upstate Medical University, United States Alysson Roncally Silva Carvalho, University of Porto, Portugal

  • The acute respiratory distress syndrome (ARDS) is the most severe form of acute respiratory failure that affects the lungs in a heterogeneous way, profoundly impairing their mechanical properties and gas-exchange functions

  • Volumetric capnography (VCap), representing the volume of CO2 expired in one breath, has specific features regarding the analysis of body CO2 kinetics that can be of great value in detecting lung overdistension by providing continuous noninvasive information on lung perfusion, convective gas transport, lung diffusion, and dead space ventilation (VD), all intimately related and sensitive to the effects of lung overdistension

Read more

Summary

Respiratory Distress Syndrome

Reviewed by: Penny Andrews, Upstate Medical University, United States Alysson Roncally Silva Carvalho, University of Porto, Portugal. Modern readily clinically available sensor technology integrates information related to pulmonary ventilation, perfusion, and gas exchange from the single analysis of expired CO2 kinetics measured at the airway opening. Current volumetric capnography (VCap), the representation of the volume of expired CO2 in one single breath, informs about pulmonary perfusion, end-expiratory lung volume, dead space, and pulmonary ventilation inhomogeneities, all intimately related to cyclic overdistension during MV. CO2 Kinetics and Lung Protection described capnodynamic method provides the possibility to continuously measure the end-expiratory lung volume and effective pulmonary blood flow. All this information is accessed non-invasively and breath-by-breath helping clinicians to personalize ventilatory settings at the bedside and minimize overdistension and cyclic deformation of lung tissue

INTRODUCTION
VOLUMETRIC CAPNOGRAPHY
DEAD SPACE SUBCOMPONENTS
VALUES OF DEAD SPACE IN PATIENTS WITH ACUTE RESPIRATORY DISTRESS SYNDROME
Critically ill anestetized ARDS
CAPNODYNAMICS FOR MONITORING LUNG STRAIN
PREDICTION OF ACUTE RESPIRATORY DISTRESS SYNDROME OUTCOME
CONCLUSION
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have