The aim of this study is to determine whether clinicians' estimates of patients' walking time agree with those determined by accelerometer devices. The walking time was measured using a waist-mounted accelerometer device everyday during the patients' waking hours. At each weekly meeting, clinicians estimated the patients' average daily walking time in the previous week. Twenty-eight clinicians completed 176 estimates of the average daily walking time for 13 patients (78.5 ± 6.6 years old) over 31 weeks. The average daily walking time measured by the accelerometers was 36.4 ± 16.2 min and that estimated by clinicians was 61.3 ± 38.4 min. Clinicians overestimated the amount of walking time by 24.8 min on average (mean% error=165.8%). Most estimates were between an hour less to 2 h more than the accelerometer measurements. Only 38.6% of the estimates agreed with the accelerometer measurements. Therefore, clinician assessment of the level of patient activity in a rehabilitation setting is highly inaccurate and unreliable.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.