Abstract

The electromigration failure phenomena of plasma etched copper lines with and without the molybdenum capping layer have been studied. Surface color change was observed during the constant current stress of the copper line. For the uncapped line, the color change is due to the copper surface oxidation from the Joule heating effect. For the capped line, it is probably due to the surface oxidation and copper diffusion to the capping layer. For the wide line, the color change near the broken point was obvious due to the local heating effect. The time dependent temperature change of the line was estimated from the resistance-to-time curve assuming that the heat dissipation to the glass substrate was negligible. The pattern of the surface color during the electromigration of the uncapped or capped copper line is a useful reference for the prediction of the line failure spot and time.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.