Abstract

This represents the first quarterly progress report on Phase 2 of the Molten Salt Coal Gasification Process Development Unit (PDU) Program. Phase 1 of this program started in March 1976 and included the design, construction, and initial operation of a PDU to test the Molten Salt Coal Gasification Process. On July 24, 1980, Phase 2 of the program was initiated. It covers a 1-year operations program utilizing the existing PDU and is planned to include five runs with a targeted total operating time of 9 weeks. The primary activities during the period covered by this report related to preparations for PDU Run 6, the initial run of the Phase 2 program. These activities included restaffing the PDU operations group, reactivation of the facility, and effecting plant modifications and improvements based on an evaluation of previous operation experience. The Melt Withdrawal System which had proven unreliable during the previous runs, was completely redesigned; thermal and flow analyses were performed; new components procured; and assembly initiated. Run 6 which is scheduled for the next report period, is aimed primarily at verifying the adequacy of the redesigned Melt Withdrawal System.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.