Deposition rates of monodisperse aerosol particles and 218Po molecules, covering a size range between 0.85 and 200 nm, were measured in a chamber made of glass. It was found that the deposition constant follows the general theory of Crump and Seinfeld ( J. Aerosol Sci. 5, 405, 1981) taking n = 2.6. Measurement of the deposition rate of 218Po molecules showed that electrical effects are of no account in chambers made of glass which are properly treated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.