Abstract
The paper describes the development of a moisture probe using the principle of laser light attenuation. The probe response was calculated for various droplet sizes and steam conditions. A calibration under known conditions in a special test facility agreed with the predictions for a fog droplet size of 0.2 μm. Using this calibration, measurements were made in a low pressure steam turbine of approximately 500 MW output. Typical distributions of moisture along the blade height are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.