Abstract

The accurate discernment and separation of chiral isomers with high precision remain a significant challenge in various industries and biological fields. In this investigation, an electrochemiluminescent (ECL) chiral recognition platform was devised to ascertain the presence of phenylalanine (Phe). Notably, a homochiral [Ni2(l-asp)2(bipy)] (Ni-LAB) was established as a dual-function coreactant accelerator and chiral recognition substrate. Ni-LAB facilitates the reaction between the coreactant (K2S2O8) and the luminescent entity 3,4,9,10-perylenetetracar-boxylic-l-cysteine (PTCA-cys), thereby enhancing the ECL luminescence efficiency and improving the sensitivity of the chiral sensor. The chiral recognition potential of Ni-LAB was assessed to differentiate between Phe chiral isomers, and the underlying mechanism was comprehensively elucidated. This system exhibited remarkable proficiency in detecting Phe enantiomers and precisely differentiating a single Phe enantiomer within a mixture, showcasing exceptional levels of selectivity, stability, and reproducibility. This study paves the way for the development of advanced chiral recognition systems, potentially revolutionizing the field of chiral sensing and discrimination.