Abstract

The Lawrence Livermore Laboratory is currently constructing a new linear induction accelerator with a higher beam current than the Astron [1] accelerator. The new accelerator, called the Experimental Test Accelerator (ETA) will be a 5-MeV, 10-kA accelerator with a pulsewidth of 50 ns. Like the Astron, the principle of magnetic induction is used to obtain a linear accelerator. The modular accelerating cavities form essentially a 1:1 transformer and the change in flux in the ferrite core induces an axial electric field for the acceleration of electrons. Since the total energy storage for the ETA is much greater than the requirement for Astron, the power system, the capacitor bank, and the modulator charging system all had to be modified to provide an overall regulation of 0.1 percent. This strict regulation of the charging voltage is necessary for pulse-to-pulse repeatability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.