Abstract
In a dc chopper converter having its load current regulated by a feedback controller of the fixed hysteresis type, the chopping frequency is shown to depend on the square of the counter EMF of the load. In a pulsewidth modulated (PWM) inverter, the counter EMF is modulated at the output frequency, so the chopping frequency is modulated at twice the output frequency. For a three-phase PWM inverter feeding a three-wire load, the chopping frequency modulation is not smooth. This is explained to be a consequence of the fact that the three phase currents must sum to zero, rendering one of the three current controllers redundant.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.