Abstract
An online model-based fault detection and isolation method for salient-pole permanent magnet synchronous motors over a finite horizon is proposed. The proposed approach combines parity-space-based residual generation and modulation-function-based filtering. Given the polynomial model equations, the unknown variables (i.e. the states, unmeasured inputs) are eliminated resulting in analytic redundancy relations used for residual generation. Furthermore, in order to avoid needing the derivatives of measured signals required by such analytic redundancy relations, a modulation-function-based evaluation is proposed. This results in a finite-horizon filtered version of the original residual. The fault detection and isolation method is demonstrated using simulation of various fault scenarios for a speed controlled salient motor showing the effectiveness of the presented approach.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.