Abstract

Cascaded multilevel inverters, such as the cascaded H-bridge (CHB) converter, are an attractive solution for multistring photovoltaic (PV) systems, because they enable direct connection to the medium voltage grid and maximum power point tracking (MPPT) of multiple strings. As a challenge of the topology, the operation with high power imbalance in the strings is constrained by the overmodulation. This limitation is analyzed for sinusoidal modulation and the impact on the maximum power imbalance is demonstrated. For increasing the operating range with maximum power tracking in the strings, a discontinuous modulation with extended maximum power imbalance and reduced losses is proposed. The method is analyzed in terms of maximum power imbalance, efficiency and power quality. In addition, the method is validated on an experimental test bench.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.