Abstract
Hollow fiber and flat sheet membranes were compared in side-by-side bench-scale experiments to evaluate whether the configuration has an impact on the rate of membrane fouling. Both microfiltration (MF) and ultrafiltration (UF) membranes were evaluated. In general, flat sheet membranes fouled more rapidly than hollow fiber membranes. Pretreatment such as coagulation generally affected both configurations similarly, but in some cases coagulation reduced fouling on hollow fiber membranes but increased fouling on flat sheet membranes. Prefiltration to remove foulants above 1 μm in size had a consistent effect on both configurations. A bench-scale apparatus employing a single-fiber module that allows testing over multiple filter runs with integral backwashing capabilities was demonstrated to provide more detailed information about fouling, which can be applied to full-scale applications. When bench-scale tests are to be used to screen treatment options for full-scale applications, the use of a backwashable hollow fiber system is recommended.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.