Abstract

Mixing only a small amount of strong base anion resin with the strong acid cation resin in a conventional water softener results in efficient uranium removal in addition to radium removal.Adding a small amount of strong base anion (SBA) resin to the strong acid cation (SAC) resin in a conventional water softener provides good uranium and radium removal. In tests on a well water containing 25 pCi/L radium and 120 μg/L uranium, a mixed bed containing 10 percent SBA and 90 percent SAC resin provided a product water with less than 1 pCi/L radium and 20 μg/L uranium during cyclic operation with sodium chloride regeneration. Additional tests indicated that too much anion resin or stratified resin beds caused excessive radium and uranium leakage. Also, potassium chloride was a superior regenerant to sodium chloride for elution of radium from the spent resin.