Abstract
This paper presents a modified vector control algorithm for a fractional-slot concentrated-winding surface permanent magnet (SPM) machine that has been developed to maximize the machine's partial-load efficiency over a wide range of operating conditions. By increasing the amplitude of the negative d-axis current, the resulting increase in the stator copper losses can be more than offset by the reduction in the iron core losses achieved by lowering the stator d -axis flux amplitude. The effectiveness of this technique has been demonstrated using both analytical models and finite element analysis for a 55-kW (peak) SPM machine design developed for a demanding set of traction drive performance requirements. For this example, the modified control strategy increases the partial-load efficiency at 20% of rated torque by > 6% at 2000 r/min compared to the maximum torque/ampere algorithm, making the machine much more attractive for its intended application.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.