A modified99mTc(Sn)-pyrophosphate (PyP) kit for the application in nuclear cardiology (radioventriculography, angiocardiography, scintigraphy of blood pool) was developed. Each vial contains 12 mg PyP (Na4P2O7), 4 mg SnCl2·2H2O, 2.5 mg gentisic acid and 10 mg NaCl. The reconstitution is performed by dissolving the lyophilized kit in 3 ml 0.9% NaCl. In comparison with the standard pyrophosphate kit for bone scanning and detection of miocardial infarction, it contains an increased amount of Sn(II) so that the molar ratio ligand/reductant is lowered from 25 to 2.5. The radiochemical analyses showed that the radiochemical purity of the labeled kit is high (>90%) during three hours after addition of99mTc-activity. The shelf-life of the inactive freeze-dried preparation is up to four months providing that it is kept in vacuum and at appropriate temperature (2–8°C). The biodistribution studies revealed increased accumulation in blood and low uptake by liver and kidneys. It was concluded that the modified kit performs stable and reproducible properties.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.