Abstract

In this paper, the Pulse Train (PT) control strategy is tentatively applied to the Parallel-connected Buck Converters (PBC) with current-sharing ability. However, in Continuous Conduction Mode, undesirable low-frequency voltage oscillation will be brought about by the PT control. Therefore, the Capacitor-Current-Feedback based PT (CCF-PT) control is newly proposed to eliminate the low-frequency voltage oscillation. The experimental results indicate that, the proposed CCF-PT control method can successfully achieve effective suppression of low-frequency oscillation by properly configuring the capacitor current feedback coefficient.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.