Abstract

BackgroundIn distal humerus fracture surgery, postoperative ulnar neuropathy is a common complication. The present study assessed the utility of the modified paratricipital approach for preventing ulnar neuropathy. This approach preserved the continuity of the attachment of the triceps with the ulnar nerve and allowed anterior subluxation of the ulnar nerve onto the hardware to be avoided. MethodsFrom December 2018 to March 2020, 13 patients who underwent surgery for distal humerus fracture through the modified paratricipital approach at our hospital were prospectively enrolled in the study. Ulnar neuropathy, Mayo Elbow Performance Score (MEPS), and Range of motion (ROM) were evaluated. ResultsNo postoperative ulnar neuropathy was observed. At the final follow-up, the mean Mayo Elbow Performance score was 97.7 (range, 85–100). The mean arc motion was 132.7° (range, 115°–145°) with a mean flexion contracture of 4.2° (range, 0°–10°) and mean flexion of 136.2° (range, 120°–145°). Hardware breakage leading to a loss of reduction occurred in one case, but the other fractures united. ConclusionsOur results demonstrated the effectiveness of the modified paratricipital approach for preventing postoperative ulnar neuropathy. The modified paratricipital approach is a safe and reliable method of performing distal humerus fracture surgery.