Abstract

Because excretion of certain nucleosides increases in all types of cancer, detection and treatment of the disease would be enhanced by rapid, simple quantitation of such nucleotides. To facilitate these analyses in urine, we have prepared a specific adsorbent for nucleosides. The affinity adsorbent gel contains an immobilized phenylboronic acid group that specifically binds cis-diols, as in ribonucleosides, which can then be quantititatively recovered by elution with acetic acid. The advantage of this boronate gel over other preparations lies in its high capacity in the swollen state (0.26 mmol/ml), so that only small volumes (less than 1 ml) of gel are required for assays. Nucelosides containing a free diol group on the ribosyl group are retained at pH 8.8 in 0.25 mol/liter salt solution with a retention volume of 15 or larger, as compared with values of 1 to 2 for the free bases. Negatively charged species (not including the boronate complex) are eluted earlier than neutral or cationic species. Added nucleosides (neutral, cationic, or anionic) are quantitatively recovered. Because pseudouridine is eluted in a unique position, this property has been used to measure it in urine. The procedures used are chemically mild. For example, we have confirmed the observation of Fink and Adams [Arch. Biochem. Biophys. 126, 27 (1968)] that urine contains N1-methyladenosine and not N6-methyladenosine, the alkaline rearranged product.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call