Abstract
Under partial shading conditions, multiple peaks are observed in the power-voltage (P- V) characteristic curve of a photovoltaic (PV) array, and the conventional maximum power point tracking (MPPT) algorithms may fail to track the global maximum power point (GMPP). Therefore, this paper proposes a modified incremental conductance (Inc Cond) algorithm that is able to track the GMPP under partial shading conditions and load variation. A novel algorithm is introduced to modulate the duty cycle of the dc-dc converter in order to ensure fast MPPT process. Simulation and hardware implementation are carried out to evaluate the effectiveness of the proposed algorithm under partial shading and load variation. The results show that the proposed algorithm is able to track the GMPP accurately under different types of partial shading conditions, and the response during variation of load and solar irradiation are faster than the conventional Inc Cond algorithm. Hence, the effectiveness of the proposed algorithm under partial shading condition and load variation is validated in this paper.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.