Abstract

The calculation method of relative sensitivity (Sr) for fluorescence intensity ratio (FIR) thermometry is discussed, taking the F33-H63 and H43-H63 transitions of Tm3+ as examples. The value of Sr is calculated using its original definition, and is found to largely deviate from the result obtained using the conventional method that is widely used at present. This deviation is found to stem from the neglect of an offset. A modified expression of Sr is proposed, which shows the true performance of FIR technology and makes it possible to precisely compare the Sr values obtained using various methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.