Abstract

Compressed-sensing (CS) accelerated 3D MR cholangiopancreatography (MRCP) could be acquired in both navigator-triggered (NT) and breath-hold (BH) mode, but the latter has been considered inferior in depicting pancreatic duct and diagnosing pancreatic duct-related diseases. To prospectively evaluate the clinical feasibility of a modified 3D BH-CS-MRCP prototype protocol with small field-of-view (FOV) and higher spatial resolution, and to compare its performance to the original BH-CS-MRCP and NT-CS-MRCP. Prospective cohort study. Eighty-two patients with suspected pancreaticobiliary diseases (46 male, median age, 55 years, range, 16-79 years), including seven noncooperative patients. 3T, CS-MRCP. Three protocols were performed in random order in each patient. Acquisition time of each protocol was recorded. Image quality, background suppression, duct visibility, and diagnostic confidence with duct anatomic variations and duct-related pathologies were rated on a 5-point scale by two blinded radiologists independently. The Wilcoxon signed-rank test was used to compare the intraindividual difference. Interobserver agreement was determined using kappa coefficients. The diagnostic performance was calculated using receiver operating characteristic curves. Acquisition time was 17 seconds for both BH-CS-MRCP protocols, and 127.5 ± 36.9 seconds for NT-CS-MRCP. In 75 cooperative patients, the incidence of major artifacts was low for all protocols (5.3-8.0%). Background suppression was similar with the two BH-CS-MRCP protocols (3.67 ± 0.77 for original BH-CS-MRCP and 3.70 ± 0. 57 for modified BH-CS-MRCP, respectively), both inferior to the NT-CS-MRCP protocol (4.41 ± 0.68, P < 0.001 for both). Modified BH-CS-MRCP and NT-CS-MRCP depicted pancreatic duct and second-level branches of biliary duct better than original BH-CS-MRCP (all P < 0.01). The diagnostic performance for detecting bile duct abnormalities was similar for all protocols (P = 0.53-0.87), whereas for detecting pancreatic duct abnormalities, modified BH-CS-MRCP and NT-CS-MRCP had significantly better performance compared to original BH-CS-MRCP (both P < 0.01). In seven noncooperative patients, NT-CS-MRCP had superior image quality than both BH protocols (both P < 0.01). Modified BH-CS-MRCP is feasible for pancreatic and biliary disorders. NT-CS-MRCP might be more useful in noncooperative patients. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1389-1399.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.