Experiments using a biased multiblock limiter in the KT-5C tokamak show that positive biasing is more effective than negative biasing in modifying the edge electric field, suppressing fluctuations and improving plasma confinement. The biasing effect varies with the limiter area, the toroidal magnetic field and the biasing voltage. By positive biasing, the edge profiles of the plasma potential, the electron temperature and the density become steeper, resulting in a reduced edge particle flux, an increased global particle confinement time and lower fluctuation levels of the edge plasma.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.