The paper proposes an application of a well-known method of Selective Harmonic Elimination in inverter's output voltage to influence an input traction current spectrum in a DC supplied traction vehicle with asynchronous motors. The aim is to reduce the values of current harmonics in frequency bands that are subject to limitations applicable on Polish railways. This paper introduces the possibility of modifying the method (Selective Harmonics Elimination — SHE) in such a way as to replace elimination of selective harmonics with their reduction (Selective Harmonics Reduction — SHR). Comparative analysis of the effectiveness of both these methods was based on computer simulation results. The important advantage of the SHR method, in comparison with the SHE methods, is the reduction of the required switching angles number with obtaining the aim of the application, i.e. current harmonics amplitudes below the defined limits. Some exemplary results of effectiveness of the proposed method are as well presented and discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.