Abstract

The modification of argon plasma-pretreated single-crystal Si(100) wafer surfaces via the UV-induced graft polymerization of poly(ethylene glycol) methacrylate (PEGMA) macromonomer (molecular weight approximately 340) for biomaterials applications was explored. The modified Si(100) surfaces were characterized by X-ray photoelectron spectroscopy and atomic force microscopy. Surface peroxide concentrations resulting from the argon plasma treatment and subsequent atmospheric exposure were determined by a coupling reaction with diphenylpicrylhydrazyl. The results suggested that a short plasma treatment time of 10 s and brief air exposure were sufficient for generating an optimum amount of peroxides and hydroperoxides for the subsequent UV-induced graft polymerization. The graft concentration of the PEGMA polymer increased with increasing PEGMA macromonomer concentration for the graft polymerization and with increasing UV graft polymerization time. The PEGMA graft-polymerized silicon surface with a high poly(ethylene glycol) graft concentration was very effective in preventing protein adsorption and platelet adhesion. The grafted PEGMA polymer layer on the Si(100) surface exhibited fairly good stability during storage in a buffer solution.