Abstract

A modification of intraocular lens (IOL) implantation, using the 4-flanged IOL fixation technique, through a 2.4 mm corneal incision using a standard cartridge and injector, is presented. An IOL with 4 eyelets is used, through which a 6-0 polypropylene suture is threaded on one side and then loaded into a provided cartridge and inserted to the anterior chamber through a 2.4 mm corneal incision. Using the handshake technique, the suture ends are eventually threaded through the eyelets and secured outside the eye with the creation of 4 flanges. This technique was used in 6 eyes of 5 consecutive patients with the absence of capsular support. During all follow-up visits, the IOLs were well centered and stable, and the flanges were buried in the sclera and covered with the conjunctiva. No complications were recorded. This modification simplifies the technique and reduces the well-known complications of large corneal incisions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.