Abstract

Cardiac surgeons are occasionally faced with ascending aorta graft kinking following ascending aorta replacement. Although it may be difficult to precisely assess the correct length of the graft during aortic clamping, while performing proximal and distal graft anastomoses on an empty heart, the major reason for graft kinking is its excessive length. Haemolytic anaemia, graft thrombosis or even heart failure have been reported as a consequence of unrecognised and uncorrected kinking of the ascending aortic graft. This paper describes a modification and improvement of an old aortic graft non-clamping technique to solve the problem of kinked tubular graft without resuming cardiopulmonary bypass.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.