Abstract

Abstract ASME Code VIII-2-2019 and previous versions provided three screening criteria for fatigue analysis. From edition 2004 to 2019, the design factor for material allowable stress decreased and the considered range of permissible cyclic number for design fatigue curve extended. However, screening criteria are almost unchanged except one restriction: If the specified number of cycles is greater than 106, then the screening criteria are not applicable and a fatigue analysis is required. In this paper, percentage limit of the design pressure in method A is modified and the specified number of cycles is extended. Some revision suggestions are also proposed to broaden the applicable range of the screening criterion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.