Abstract

The Pelorus Mark III Stereotactic System is a commercially available device for CT-guided stereotactic brain biopsy in people. With relatively minor modifications, this device was used to safely and accurately perform CT-guided stereotactic brain biopsies in 50 dogs with intracranial lesions. Modifications were necessary to accommodate a 90 degree shift in orientation of the canine head compared to the human head during the imaging phase of the procedure, and to facilitate other phases of the biopsy procedure that are affected by the uneven and variable topography of the canine skull. Description of a typical CT-guided brain biopsy procedure in dogs using the modified Pelorus Mark III Stereotactic System is provided. Accuracy of biopsy needle placement was determined by comparing the x, y and z coordinates of the biopsy target site with the actual coordinates of the needle tip on CT images. Mean needle placement error was 3.5 +/- 1.6 mm. Needle placement error was not significantly related to operator experience, dog size (body weight), or needle path length, however, needle placement error was significantly affected by lesion location.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.