Abstract
Abstract Because of the increasing demand for energy in the recent period, it has become necessary to intensify the study in the field of evaluating the performance of the gas station under the first and second laws efficiency. The energy and exergy losses of gas stations are represented by the compressor, combustion chamber, and turbine. Therefore, this work aims to analyze the energy and exergy of a 55 MW Taza gas power station. The investigation demonstrated that the most significant misfortunes of the exergy happened in the combustion chamber, where was 66.5MW the most minimal misfortunes in the compressor 5MW while the misfortunes in the turbine 8.4MW. The thermal efficiency of the gas turbine power plant was 33.06%, while the exergy efficiency was 32.39%. The novelty of the current work concentrated on obtaining the Grassmann graph for each component.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.