Abstract

This study determined the impact of selected chemical protective coveralls (CPC) on physiological responses and comfort sensations. Fifteen males exercised at approximately 6 METS in three CPC (Tyvek®, Gulf and Tychem®) and a control garment. Physiological strain was characterised by core and skin temperatures, heart rate, , perceived exertion, hotness and wetness. Physical burden was characterised by restriction to movement, and RPE. The highest levels of physiological strain and physical burden were found in Tychem®, and the lowest in control. Seven statistical regression models were developed through correlation and multiple regression analyses between the human responses and the results from previously conducted fabric and garment property testing. These models showed that physical burden was increased by adding weight and/or restricting movement. Oxygen consumption was best predicted by clothing weight and fabric bending hysteresis. Fabric evaporative resistance and thickness were the two best predictors of physiological and perceptual responses.