Abstract

The fire resistance of precast prestressed concrete floor systems is heavily influenced by the end connections and the stiffness of the surrounding structure, both of which must be considered in any analysis. Analysing floor slabs with beam or shell elements whose end nodes share the nodes of supporting beams leads to a major problem for precast prestressed flooring systems where the steel tendons terminate at the end of the flooring units, because the approach of sharing nodes of the supporting beam and floor assumes that these tendons are anchored into the supporting beams. In order to solve this problem, a "multi-spring" connection element has been developed. Experimental data available from previous research work has been used to validate the finite element model. It is concluded that the inclusion of the multi-spring connection results in more accurate predictions of prestressed hollowcore slab behaviour in fire conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.