The use of a cohesive zone model (CZM) to predict the long-term durability of adhesively bonded structures exposed to humid environments has been investigated. The joints were exposed to high relative humidity (RH) environments and immersion in both tap and deionised water for up to a year before quasi-static testing to failure. Both stressed and unstressed conditions during aging were considered. The degradation was faster for the stressed joints and for those joints immersed in the more corrosive environments. Two mechanisms were suggested to explain this behaviour: cathodic delamination and stress-enhanced degradation. In the model, the cohesive zone parameters determine the residual strength of the joints. The degradation of these parameters was, in the first instance, related directly to the moisture concentration. The model was then extended to include degradation due to stress and more corrosive environments. Good correlation between the numerical modelling and the experimental results was obtained.