Experiments were made for welding current variation between 6kA and 12kA. Microstructure and mechanical performance under tensile-shear tests were recorded and compared. Welding current effect on micro-properties was very slight while nugget size was highly dependent on welding current. Expulsion phenomenon existed at 12kA welding current and the unsatisfactory partial interfacial failure was detected. Nugget formation and temperature distribution were analysed numerically. Comparisons with experimental results showed that the nugget size deviation was within 10% and the nugget shape was well predicted.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.