Abstract
This article describes a control method called "direct power control" designed specifically for parallel active power filters. The purpose of this method is to attenuate harmonics in the supply current and offset reactive power problems. The main goal is to bring the active power and reactive power back to the reference values through hysteresis control. The output of the hysteresis controller is combined with the switching table to regulate active and reactive power in real time by determining the optimal switching configuration of the inverter. This study proposes a novel switching table design based on analyzing the impact of the inverter switching vector on the instantaneous reactive and active power derivatives. The goal is to reduce the number of commutations by eliminating zero vectors while maintaining the required DC bus voltage using anti-windup techniques based on PI controllers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Annals of the University of Craiova Electrical Engineering Series
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.