Abstract

This paper presents the modelling, simulation and comparative study between switched reluctance generator 8x6 and switched reluctance generator 12x8. During work, the structural properties of the rotor and stator laminates of these machines are exposed. This information was used to perform mathematical modelling for both topologies. Based on this modelling, a computer simulation model was developed in the Simulink/Matlab® environment where several tests were carried out. To ensure comparability between machines, the output power in both topologies was set to 735,5 VA. After analyzing the results obtained during the simulations, it was found that the topology of the switched reluctance generator 8x6 is more efficient than 12x8

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.