Abstract
A new method of measuring the properties of hollow fibre membranes for modelling purposes was developed. Measuring the gas permeability as a function of membrane length and extrapolating to zero length provided enough membrane material information for modelling the flux. These values resulted in the predicted Vacuum Membrane Distillation (VMD) flux within the experimental errors (±5%) for different velocities. The predicted results at different temperatures were mostly within the experimental variation range. However, the error (<10%) was greater at the highest temperature tested, perhaps due to water evaporation in the feed tank. Additionally both the modelling and experimental results show that the flux in VMD was independent of the module packing density under the presented conditions. The results also show that the mathematical model predictions agree well with the experimental results of short experimental duration (1–2h).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.