Abstract

Metabolomics is a powerful and widely used approach that aims to screen endogenous small molecules (metabolites) of different families present in biological samples. The large variety of compounds to be determined and their wide diversity of physical and chemical properties have promoted the development of different types of hydrophilic interaction liquid chromatography (HILIC) stationary phases. However, the selection of the most suitable HILIC stationary phase is not straightforward. In this work, four different HILIC stationary phases have been compared to evaluate their potential application for the analysis of a complex mixture of metabolites, a situation similar to that found in non-targeted metabolomics studies. The obtained chromatographic data were analyzed by different chemometric methods to explore the behavior of the considered stationary phases. ANOVA-simultaneous component analysis (ASCA), principal component analysis (PCA) and partial least squares regression (PLS) were used to explore the experimental factors affecting the stationary phase performance, the main similarities and differences among chromatographic conditions used (stationary phase and pH) and the molecular descriptors most useful to understand the behavior of each stationary phase.

Highlights

  • Over the past decade, metabolomics has received considerable attention from the scientific community

  • Due to its high-resolution power, sensitivity and accuracy of m/z detection, liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) has become the analytical platform most used in metabolomics studies

  • Reversed phased liquid chromatography (RPLC) is not recommended for the analysis of some of the most usual metabolite families characterized as being polar and hydrophilic compounds [2,6,7,8,9]

Read more

Summary

Introduction

Metabolomics has received considerable attention from the scientific community. Like ANOVA-simultaneous component analysis (ASCA) [19], can help evaluating the statistical significance of the experimental factors involved in a non-targeted metabolomics study, such as when different HILIC stationary phases and mobile phase conditions are assessed. On the other hand, building models linking the physicochemical properties of compounds (molecular descriptors, MDs) and their chromatographic behavior (retention factors) could help to get a different insight into the HILIC stationary phase performance [11,20,21,22,23,24,25,26,27,28,29]. Partial least squares regression (PLS) models based on MDs computed from molecular structures of different metabolite families were calculated for evaluating the chromatographic behavior of the four HILIC stationary phases considering the retention factor of the analyzed metabolites

Determination of Retention Factors
Retention factors for for the the 54
Evaluation of HILIC Stationary Phases Behavior
Exploratory
Partial
Methods
Instrumentation
Retention Factor Determination
Molecular Descriptors Determination
Evaluation of HILIC Chromatographic Performance
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.