Abstract

A finite-volume model has been developed and applied to compute the fluid flow distribution inside the liquid zone in a mould region of a continuous strip casting machine. The model was produced with the commercial program CFX, which allows this nonlinear, highly turbulent problem to be simulated using the k-e turbulence model. The predicted flow patterns were compared with experimental observations and measurements conducted using a transparent plastic water model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.